Monitoring and Control

CPS SZ5 20 Power Source Zone

Monitoring and Control

CPS
SZ5 20
Power Source Zone

Overige eigenschappen
Housing excluding connectors
21 x 18 x 11 cm (lxwxh) Input
DC range
10-36 VDC
Design power demand
24 W Output adjustable supply
Maximum output power
20 W
Voltage control range
0-10 VDC
Resolution control range voltage
40 mV
Control range current
0-10 A
Resolution control range current
40 mA
Efficiency
approx. 95% Measurement connections
Connections
6 channels simultaneously from to reading
Response time
0,26 ms
Measurement resolution
1 mV
Input impedance
1 G Ω
Depolarisation measurement
Power supply is digital switched off by means or a relay and galvanic disconnected on both poles
Operating range
-25 ºC to 65 °C without derating Connections
Input
2-way 3 x 2,5 mm² QPD-connector for power supply 24 VDC with earth
Output
3-way 4 x 2,5 mm² QPD-connector Cathode, Anode and 2 reference cells per connector
  • Housing excluding connectors • 21 x 18 x 11 cm (lxwxh)
  • Input
  • DC range • 10-36 VDC
  • Design power demand • 24 W
  • Output adjustable supply
  • Maximum output power • 20 W
  • Voltage control range • 0-10 VDC
  • Resolution control range voltage • 40 mV
  • Control range current • 0-10 A
  • Resolution control range current • 40 mA
  • Efficiency • approx. 95%
  • Measurement connections
  • Connections • 6 channels simultaneously from to reading
  • Response time • 0,26 ms
  • Measurement resolution • 1 mV
  • Input impedance • 1 G Ω
  • Depolarisation measurement • Power supply is digital switched off by means or a relay and galvanic disconnected on both poles
  • Operating range • -25 ºC to 65 °C without derating
  • Connections
  • Input • 2-way 3 x 2,5 mm² QPD-connector for power supply 24 VDC with earth
  • Output • 3-way 4 x 2,5 mm² QPD-connector Cathode, Anode and 2 reference cells per connector

Gerelateerde producten